22k human genome array chip Search Results


90
CapitalBio Corporation agilent 22 k human 70-mer oligonucleotide microarray
Agilent 22 K Human 70 Mer Oligonucleotide Microarray, supplied by CapitalBio Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/22k+human+genome+array+chip/human+genome+70+mer+oligonucleotide+microarray/pmc04002275-238-4-8
Average 90 stars, based on 1 article reviews
agilent 22 k human 70-mer oligonucleotide microarray - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
CapitalBio Corporation human 22 k oligo chips
Human 22 K Oligo Chips, supplied by CapitalBio Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/22k+human+genome+array+chip/human+22+k+oligo+chips/pmc03921456-42-3-13
Average 90 stars, based on 1 article reviews
human 22 k oligo chips - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
CapitalBio Corporation gpl5918 capitalbio human 22k oligonucleotide microarray
Gpl5918 Capitalbio Human 22k Oligonucleotide Microarray, supplied by CapitalBio Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/22k+human+genome+array+chip/human+long+oligonucleotide+microarray/pmc09254876-78-16-17
Average 90 stars, based on 1 article reviews
gpl5918 capitalbio human 22k oligonucleotide microarray - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
CapitalBio Corporation cdna microarray chip 22k human genome array chip
Gene expression in colon carcinoma samples compared to adjacent peritumor samples as determined by <t>microarray.</t> The red signals represent higher expression of genes and the green signals represent lower expression of genes.
Cdna Microarray Chip 22k Human Genome Array Chip, supplied by CapitalBio Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/22k+human+genome+array+chip/cdna+microarray+analysis/pmc03493704-49-1-9
Average 90 stars, based on 1 article reviews
cdna microarray chip 22k human genome array chip - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
CapitalBio Corporation 22k human genome array gene chips
Gene expression in colon carcinoma samples compared to adjacent peritumor samples as determined by <t>microarray.</t> The red signals represent higher expression of genes and the green signals represent lower expression of genes.
22k Human Genome Array Gene Chips, supplied by CapitalBio Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/22k+human+genome+array+chip/22k+human+genome+array/pm28485160-80-1-13
Average 90 stars, based on 1 article reviews
22k human genome array gene chips - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Cytiva Europe 22k operon v2 1 human genome oligo microarray chip
Comparison of mRNA expression in seven candidate genes between TPCH test (n = 30, <t>microarray)</t> and training set (n = 62 qRT-PCR data), with two public microarray datasets of lung tissue samples (Spira et al , , n = 34; and Golpon et al , n = 10) . Fold change represents mean expression ratio of moderate versus mild emphysema (TPCH training set), severe/mild emphysema versus normal (Spira et al ), or severe emphysema versus normal samples (Golpon et al ). The absence of a bar indicates the gene was not represented on the microarray platform.
22k Operon V2 1 Human Genome Oligo Microarray Chip, supplied by Cytiva Europe, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/22k+human+genome+array+chip/UCB-HES+Sepax+2+protocol+software/pmc02746189-65-27-18
Average 90 stars, based on 1 article reviews
22k operon v2 1 human genome oligo microarray chip - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
CapitalBio Corporation 22 k oligonucleotide microarrays
Comparison of mRNA expression in seven candidate genes between TPCH test (n = 30, <t>microarray)</t> and training set (n = 62 qRT-PCR data), with two public microarray datasets of lung tissue samples (Spira et al , , n = 34; and Golpon et al , n = 10) . Fold change represents mean expression ratio of moderate versus mild emphysema (TPCH training set), severe/mild emphysema versus normal (Spira et al ), or severe emphysema versus normal samples (Golpon et al ). The absence of a bar indicates the gene was not represented on the microarray platform.
22 K Oligonucleotide Microarrays, supplied by CapitalBio Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/22k+human+genome+array+chip/22+k+oligonucleotide+microarrays/pmc03461817-255-3-8
Average 90 stars, based on 1 article reviews
22 k oligonucleotide microarrays - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
CapitalBio Corporation oligonucleotide microarray 22 k
Comparison of mRNA expression in seven candidate genes between TPCH test (n = 30, <t>microarray)</t> and training set (n = 62 qRT-PCR data), with two public microarray datasets of lung tissue samples (Spira et al , , n = 34; and Golpon et al , n = 10) . Fold change represents mean expression ratio of moderate versus mild emphysema (TPCH training set), severe/mild emphysema versus normal (Spira et al ), or severe emphysema versus normal samples (Golpon et al ). The absence of a bar indicates the gene was not represented on the microarray platform.
Oligonucleotide Microarray 22 K, supplied by CapitalBio Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/22k+human+genome+array+chip/oligonucleotide+microarray/pm23958878-51-3-22
Average 90 stars, based on 1 article reviews
oligonucleotide microarray 22 k - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


Gene expression in colon carcinoma samples compared to adjacent peritumor samples as determined by microarray. The red signals represent higher expression of genes and the green signals represent lower expression of genes.

Journal: Experimental and Therapeutic Medicine

Article Title: Altered expression levels of IDH2 are involved in the development of colon cancer

doi: 10.3892/etm.2012.676

Figure Lengend Snippet: Gene expression in colon carcinoma samples compared to adjacent peritumor samples as determined by microarray. The red signals represent higher expression of genes and the green signals represent lower expression of genes.

Article Snippet: A cDNA microarray chip (22K Human Genome Array Chip; CapitalBio, Co., Ltd., Beijing, China) was used for the tumor or peritumor tissue samples in this study.

Techniques: Gene Expression, Microarray, Expressing

Comparison of mRNA expression in seven candidate genes between TPCH test (n = 30, microarray) and training set (n = 62 qRT-PCR data), with two public microarray datasets of lung tissue samples (Spira et al , , n = 34; and Golpon et al , n = 10) . Fold change represents mean expression ratio of moderate versus mild emphysema (TPCH training set), severe/mild emphysema versus normal (Spira et al ), or severe emphysema versus normal samples (Golpon et al ). The absence of a bar indicates the gene was not represented on the microarray platform.

Journal: Respiratory Research

Article Title: Expression profiling identifies genes involved in emphysema severity

doi: 10.1186/1465-9921-10-81

Figure Lengend Snippet: Comparison of mRNA expression in seven candidate genes between TPCH test (n = 30, microarray) and training set (n = 62 qRT-PCR data), with two public microarray datasets of lung tissue samples (Spira et al , , n = 34; and Golpon et al , n = 10) . Fold change represents mean expression ratio of moderate versus mild emphysema (TPCH training set), severe/mild emphysema versus normal (Spira et al ), or severe emphysema versus normal samples (Golpon et al ). The absence of a bar indicates the gene was not represented on the microarray platform.

Article Snippet: Lung and universal reference RNA (Stratagene, La Jolla, CA, USA) was reverse transcribed, labeled with Cy5 and Cy3 (Amersham/GE Healthcare, Buckinghamshire, England) respectively and co-hybridized onto a 22K Operon V2.1 Human Genome Oligo Microarray chip http://www.operon.com containing 21,329 70 mer probes representing ~14,200 named transcripts printed by the British Columbia Gene Array Facility http://www.microarray.prostatecentre.com .

Techniques: Expressing, Microarray, Quantitative RT-PCR